Add to Cart
Psa Industrial/Medical Oxygen Generator Medical Oxygen Gas Generation Plant
1. Equipment Installation Condition
oxygen capacity | 3-400Nm3/h |
oxygen purity | 93%+-3% |
output pressure | 0.1-0.4MPa(1-4Bar) adjustable / 15MPa filling pressure offered |
2. Oxygen Generator Specification
Specification | output (Nm³/h) | Effective gas consumption (Nm³/h) | air cleaning system |
CBO-5 | 5 | 0.95 | KJ-1 |
CBO-10 | 10 | 2.1 | KJ-2 |
CBO-20 | 20 | 4.0 | KJ-6 |
CBO-40 | 40 | 8.2 | KJ-10 |
CBO-60 | 60 | 12.3 | KJ-12 |
CBO-80 | 80 | 16.3 | KJ-20 |
CBO-100 | 100 | 20.8 | KJ-20 |
CBO-150 | 150 | 30.7 | KJ-30 |
CBO-200 | 200 | 41 | KJ-40 |
3. Process Flow Brief Description
4. Technical Features
1). Full Automation
All systems are designed for un-attended operation and automatic Nitrogen demand adjustment.
2). Lower Space Requirement
The design and Instrument makes the plant size very compact,assembly on skids,prefabricated from factory.
3). Fast Start-up
Start-up time is only 5 minutes to get desired Nitrogen purity.So these units can be switched ON&OFF as per Nitrogen demand changes.
4). High Reliabiity
Very reliable for continuous and steady operation with constant Nitrogen purity.Plant availability time is better than 99% always.
5). Molecular Sieves life
Expected Molecular sieves life is around 15-years i.e. whole life time of nitrogen plant.So no replacement costs.
6). Adjustable
By altering flow,you can deliver nitrogen with precisely the right purity.
5. How it works ?
The raw air will be removed its particle by inlet filter and then be pressurized to about 40Kpa.
The air temperature from the air blower is about 75C, after to be cooled by cooling water, it will flows into one of adsorption tower which filled with adsorber.When the raw air flows from the bottom tower to upper tower, the
nitrogen will be adsorbed, oxygen will be oncentrated at the top of tower and be delivered out as product gas.
When the adsorber almost reaches to saturation, in the action of controller, the valves will be switched, the rawair flows into annotheradsorption tower to adsorb. Saturated adsorption tower will be decompressurized to atmosphere pressure andthen be vacuumized to about -60Kpa,product gas will be introduced into the tower to pruge the adsorption bed, thereby,the adsorber will bedesorbed, and prepare for the next cycle.
The two adsorption towers adsorb and desorb alternately to produce oxygen gas continuously.Raw air shifting from one adsorption tower to another tower is controlled by pneumatic valves, the action process of valves is realized by PLC controller. Centralized control system enables the whole system to work automatically.